Following publication in the Official Gazette on 29 March 2025, sending data to e-Nabız (Türkiye’s national personal health record system) is now mandatory for private healthcare providers. Audits and fines have begun for clinics that have not migrated by 2026. This guide lists the steps that will help you complete compliance within four weeks — whether or not you have a technical team.
Who does the obligation cover?
- Private practices, polyclinics and medical centres
- Dental clinics and private dental hospitals
- Physical therapy, dietitian and psychology clinics
- Genetics, laboratory and imaging centres
Note
Whether or not the institution has an SGK agreement does not change the compliance obligation. Data must be submitted for every patient you provide healthcare services to.
Technical requirements
e-Nabız integration is based on the HL7 FHIR R4 standard. A mutually TLS-certified channel is established between the Ministry of Health endpoint and your institution’s software. Transmission cannot begin until the following three components are in place.
- A Sağlık-Net user account and an authorised physician DHY (physician authorisation) record
- An institutional certificate (SHS) and a facility signing key
- A FHIR-compliant database schema: the Patient, Encounter, Observation and Condition resources are mandatory
Seven common mistakes clinics make
- Entering diagnoses as free text instead of SNOMED CT (these are rejected)
- Omitting patient contact details alongside the national ID number
- Sending Encounter start/end times in local time instead of UTC
- Entering medical device results manually without linking a DICOM reference
- Confusing the test (sandbox) endpoint with the production endpoint
- Not queueing failed messages in the workflow — messages that drop on the third attempt are lost
- A KVKK privacy notice that does not mention e-Nabız transmission
A four-week compliance roadmap
Week 1 — Certificates and user management
Start your Sağlık-Net registration application (1–3 business days). In parallel, request the institutional SHS certificate through KamuSM. If your physicians’ e-signature cards are ready, the DHY application is approved within 24 hours.
Week 2 — Data schema mapping
Map the fields in your current record-keeping system to FHIR resources. If your diagnosis codes are already ICD-10 you will not need a conversion table; but if you have free-text diagnoses, converting the 50 most frequent diagnoses per physician to ICD-10 costs about a day.
Week 3 — End-to-end testing in the sandbox
Send at least 100 real anonymised records in the Ministry’s test environment. Log the response (ACK/NACK) for every submission. Place failed messages in a dead-letter queue fed by a three-retry rule.
Week 4 — Go-live and monitoring
We recommend running in parallel for the first week: the old manual submission and the automated system both operate at the same time. After seven days you can switch off manual submission. If your daily success rate falls below 98%, review your retry logic.
Manual e-Nabız submission took one staff member six hours a week. After integration that dropped to zero, and our error rate fell from 14% to 0.3%.
Ayşe K., IT Director, 80-bed private hospital
Frequently asked questions
What happens when a patient withdraws e-Nabız consent?
You must stop sharing data the moment consent is withdrawn. If the system you use does not support a per-patient opt-out flag, you fall into the trap of manual tracking — this is a critical requirement.
Do I need to replace my current HBYS?
Not necessarily, but if your current system does not produce FHIR output you will need to write an adapter layer on top of it. That layer usually costs less than migrating to a new HBYS (hospital information management system) — although it is expensive to maintain in the long run.
TRtek note
TRtek HBYS and clinical software are compatible out of the box with e-Nabız, Sağlık.Net, MHRS and MEDULA integrations. You can schedule a demo to discuss our migration support.